What to Check in a TCCA or Cal Hypo SDS and COA Before Importing
Check two things before you import pool chlorine. The safety data sheet (SDS) must describe the exact product you are buying. The certificate of analysis (COA) must belong to the batch you are shipping. In the US, the SDS is also your own legal file as the importer 3. That means you answer for what it says, and your customers get it from you. If either check fails, ask the supplier to fix it before the goods are loaded.
We supply TCCA (trichloroisocyanuric acid, or trichlor), calcium hypochlorite (cal hypo) and dichlor (sodium dichloroisocyanurate, or SDIC) to importers. Our quote comes with the SDS for the grade. The test results for the batch you buy come before loading. These are the checks we would run on any supplier's files, ours included.
- The SDS covers the product. The COA covers one batch. A lab report covers one sample.
- Check the SDS before the first order: format, revision date and Sections 2, 9, 10 and 14.
- Dichlor ships two ways. Under US transport rules, the dry form is an oxidizer. The dihydrate is not, and is not regulated as hazmat unless it meets another hazard class.
- Check the COA when the goods are ready: batch number, limits and results.
SDS, COA and lab report: what each one proves
Each file proves something different, and none can stand in for another.
A supplier may send three files. They look alike, but each one proves something different.
The SDS describes the product. It covers the hazards, safe handling and how the goods ship. Its first section names the product by the same name used on its label 11. So one SDS fits every batch of that product.
The COA is the test sheet for one batch. Our TCCA tablet COA, for example, is issued for one named batch only. The next batch gets its own COA.
A lab report from a testing company covers the sample that was sent to the lab. We hold a third-party lab report on a cal hypo sample we sent in. It records that the lab tested the sample as the applicant instructed 10. That report speaks for the sample, and each batch we ship also gets its own COA.
So one file cannot stand in for another. A lab report does not prove your container, and an old COA does not prove a new batch.
Ask a new supplier for all three files as one set. At the quote stage, these files help you judge the supplier. The COA for the batch you actually ship is a separate file, and it has to come with that shipment before loading. Name the product, the grade and the form, such as TCCA 90% tablets. Ask that every file uses that same name. Our guide to supplier checks before ordering covers the rest of the supplier review. You can ask for the SDS with your quote.
Can you use the supplier's SDS in the US? Check language, layout and date
Use the supplier's SDS as your starting point, but check it before the first order. The supplier may send an SDS written for EU rules, or one that is years old. An EU file can still be a useful starting point, but it follows another rulebook. Check it against the three points below. If it fails one, ask for a US version early, because it takes time.
Start with three format checks. The content checks for Sections 2, 9, 10 and 14 follow below.
Language and layout. The SDS must be in English 3. It must carry the 16 numbered section headings in the standard order 3. A heading cannot just be left blank. If there is nothing to report, the SDS must say no applicable information was found 3.
A clear revision date. Section 16 must show when the SDS was prepared or last revised 3.
Note: Section 16 gives the revision date; compare that date, not the file or email date. 3
Kept up to date. Whoever prepares the SDS, the maker or you as the importer, must add important new facts about a hazard within three months 3. So if the revision date is old, ask the supplier whether anything has changed since. You must send the SDS with your first shipment to each customer. You must send it again with the first shipment after an update 3.
OSHA, the US workplace safety agency, sets these rules under its Hazard Communication Standard. OSHA does not check what Sections 12 to 15 say, but the headings must still be there 3. Your carrier still reads Section 14, so it gets its own check below.
If a file shows several dates, or none, ask for its revision history. OSHA suggests asking the supplier to explain what changed between versions 11. If you buy across our Disinfectants range, ask for each product's SDS separately.
Sections 2, 9 and 10: does the SDS describe the chemical you are buying?
Three sections tell you whether the SDS fits the goods. Section 2 lists the hazards. Section 9 says what the product looks like and how acidic it is. Section 10 lists what it must never touch. If these do not fit, the SDS was probably written for another product or grade.
Section 2, hazards. It must give the hazard class, a signal word and the hazard statements 11. TCCA is a strong oxidizer, a chemical that feeds a fire 5. So Section 2 should class it as an oxidizing solid. A TCCA or cal hypo SDS with no oxidizer class is a red flag.
Cal hypo is a strong oxidizer too, more so when wet or warm 1. Oxidizer is not always the only hazard. Our 70% cal hypo SDS also classes it as corrosive to skin 9.
Dry dichlor (CAS 2893-78-9) needs an oxidizer class too. The international safety card classes it as an oxidizer that may intensify fire 6. So a dry dichlor SDS without that class is a red flag. A dihydrate SDS may not list one. Settle the form first from Section 3 and the Section 14 part, then judge Section 2.
Section 9, properties. It must describe the product's appearance and give its pH, among other figures 11. Check that the form matches your order: powder, granules or tablets. TCCA dissolves into an acidic solution in water, about pH 3 as a rough guide 12; our own past-batch COA gives a range of 2.7–3.3, measured in a 1% solution. A TCCA SDS that shows a neutral pH is a reason to ask questions. When you compare the Section 9 pH with a COA, check that both name the same test concentration. For dichlor, compare the Section 9 pH with the pH line on the COA for the same grade.
Section 10, stability and reactivity. It must list the materials the product reacts with 11. For TCCA, that list matters if you buy more than one chlorine. TCCA mixed with cal hypo and water can react explosively 2. It also reacts violently with ammonia compounds and with soda ash, a common pool chemical 5. Contact with water can make it give off chlorine gas 2.
Example: If you import both TCCA and cal hypo, the Section 10 line on calcium hypochlorite is the reason they are stored apart. 2 11
SDS check before ordering. Run this list on each supplier SDS. A "no" on any line means asking for a corrected SDS before you confirm the order.
- It is in English, with the sixteen headings in order and empty items marked.
- Section 16 gives a revision date you can find.
- For TCCA, cal hypo and dry dichlor, Section 2 shows an oxidizer class.
- Section 9 form and pH fit the goods.
- Section 10 lists what the product must not touch.
- Section 14 fits the product and its form, as the next section explains.
Put the lists from each SDS side by side. You will see which products cannot share a warehouse bay. Our guide to the storage conditions the SDS requires shows how to keep them apart. If you are still choosing a chlorine, see TCCA against the other solid chlorines.
Section 14: the transport line, and why dichlor depends on its form
Section 14 is the line your freight forwarder reads to book the shipment. It gives the UN number, a four-digit code that tells the carrier what the cargo is. TCCA ships as an oxidizer, which carriers treat as dangerous goods. So does hydrated cal hypo. Dichlor depends on its form. If Section 14 does not match the goods or the booking, the shipment can be re-booked or held.
Section 14 lists the UN number, the proper shipping name, the hazard class and the packing group 11. The proper shipping name is the exact name the goods must be booked under. The packing group ranks the danger within a class. It also says whether the product is a marine pollutant 11; check that line with your forwarder when you book.
| TCCA | Cal hypo, hydrated | Dichlor, dry | Dichlor, dihydrate | |
|---|---|---|---|---|
| UN number | UN2468 | UN2880 | UN2465 | Per its SDS |
| Oxidizer (Division 5.1) | Yes | Yes | Yes | No (US)* |
| If classed as corrosive for transport | Per its SDS | UN3487 (5.1 + 8) | Per its SDS | Ships under that class (SP 28) |
"SP 28" and the asterisk refer to US special provision 28; the dihydrate entry below gives the full condition. The TCCA and dry dichlor entries come from the US hazmat table. TCCA is Packing Group II, and Division 5.1 is the class for oxidizers 4.
Cal hypo. Cal hypo with 5.5% to 16% water is UN2880, Division 5.1 4. If the product is classed as corrosive for transport, the US hazmat table has a separate hydrated entry, UN3487. It is Division 5.1 with a Class 8 subsidiary hazard 4. Dry cal hypo above 39% available chlorine is UN1748 4, or UN3485 if corrosive 4. So ask the supplier which entry its SDS uses, and why. Our guide to UN numbers and HS codes lists the full entries.
Dichlor, dihydrate. This form holds a little water in its crystals. A US rule, special provision 28, sets it apart from the dry form. It is not Division 5.1, and it is not regulated as hazmat unless it meets another hazard class 4.
So for dichlor, confirm the form before you read Section 14. Look at the CAS number in Section 3. A CAS number is a chemical's ID, the same in every country. Dry dichlor is CAS 2893-78-9, and the dihydrate is CAS 51580-86-0 8. For every leg, by road or by sea, book the dihydrate under the transport class on that grade's SDS.
OSHA does not enforce what Section 14 says 11. The transport rules decide whether it is right: the US DOT hazmat rules, and the IMDG Code at sea. Your forwarder and carrier check it against them. So check it against the booking as well as the goods.
For any lot, read the CAS number in Section 3 and the transport line in Section 14 of that grade's SDS, the one sent with the lot, before you book.
Reading the batch COA: the lines that matter and the batch number
First check that the COA belongs to your goods. The batch number and quantity must match the drum labels and the packing list. Then check each test line. The supplier's limit sits next to each result. Check that every result is inside that limit, and that the limit matches your contract.
Here is how one of our own COAs reads, from one past batch of our TCCA tablets, shown only to explain the layout.
| TCCA tablets, one past batch | Limit | Result |
|---|---|---|
| Available chlorine | 90% min | 90.04% |
| Moisture | 0.5% max | 0.37% |
| pH, 1% solution | 2.7–3.3 | 3.0 |
Figures from that past batch's COA. Available chlorine is the strength figure, and moisture is the water content. Compare the limits with our TCCA 90% specification or with your own contract.
The same COA gives an expiry date; on the COA for your own batch, check that date is still ahead of your sale.
Our cal hypo 70% COA, also a past batch kept for reference, reads the same way. Available chlorine is 70% minimum, and the batch tested 71%. Moisture is 4% to 10%, and the batch tested 8.1%. If the water result is outside the hydrated range in the Section 14 part above, ask the supplier which cal hypo entry its SDS uses, and why.
The COA names the Chinese standard it was graded against. That batch's COA also gives a one-year validity. That is what this one COA said, not a general shelf life for cal hypo. Our range is listed under calcium hypochlorite 65% / 70%. Our guide covers the cal hypo COA limits in more detail.
Our cal hypo 65% granular COA sets moisture at 4% to 8%. That batch tested 5.5%. Limits change with the grade, even within one product. Our dichlor 56% COA allows 4% to 8% moisture, and its batch came in at 6.15%. Our dichlor 60% COA caps moisture at 5%, and its batch came in at 3.56%. So read each limit against your own contract, not against another grade's COA.
A good COA names its test method or standard, so you know how each figure was found. The dichlor specification measures available chlorine by iodine titration: the sample frees iodine, and the lab measures it with a standard solution 7.
COA check before loading. Any line that fails goes back to the supplier before loading.
- The batch number and quantity match the drums and the packing list.
- Every limit matches your contract.
- Every result sits inside its limit.
- The expiry or validity date is still ahead.
- The test method or standard is named.
Not at the factory at loading? Ask the supplier for a photo of a drum label that shows the batch number. Compare it with the COA. When the goods arrive, check the labels again and file the photo with the COA. If a customer later complains, you can show which batch was tested.
When the files don't match: what to ask, and in which order
When the files disagree with each other or with the goods, fix it before loading. A fix costs an email before loading. After loading, it can cost a re-booking or a held container. Ask the supplier for a corrected document, in the order below. Product and grade come first, because they change the SDS and the transport class for every batch. Batch problems come after that, because they affect only this shipment.
- Product and grade first. If the SDS names another product or grade, ask for the right SDS. A revised SDS may show what changed from the last version 11. Once you have the new version, send it to your customers with your first shipment after the update 3.
- Transport line second. Say Section 14 shows dichlor as UN 2465, but you were told it is dihydrate. Ask the supplier for the written basis, and ask your forwarder to confirm it. If the supplier says the product meets another hazard class, ask which class, in writing 4. This is a fair question for any supplier, us included.
- Then the batch. If the COA names another batch, ask for the COA of the batch being shipped.
- Results outside your contract. A result may sit outside your limit, or the goods may differ from the contract. Then raise it under your contract and hold loading until it is settled.
For a first order or a new supplier, a check on the goods themselves adds a layer. We accept an inspector the buyer appoints to check the goods at container loading.
Approve the order when the files agree with each other
Approve the order when the files agree with each other and with the goods. The SDS is current, in US format, and describes your product, grade and form. Its Section 14 fits that form. The COA belongs to the batch being shipped, and every result is inside your contract.
Anything that does not line up goes back to the supplier before loading. Next step: ask for the SDS of the grade with your inquiry. Ask for the shipped batch's COA before loading.
More guides on shipping files sit under Documents, Compliance & Shipping.
References
- NOAA CAMEO Chemicals: Calcium hypochlorite mixture, dry
- NOAA CAMEO Chemicals: Trichloro-s-triazinetrione, dry
- eCFR 29 CFR 1910.1200 Hazard Communication (up to date as of 10/21/2026) — Originally published: 2026-10-14; Version read: 2026-10-21
- eCFR 49 CFR Part 172 Subpart B: Hazardous Materials Table and Special Provisions — Originally published: 2026-10-13; Version read: 2026-10-21
- ILO/WHO International Chemical Safety Card 1675: Trichloroisocyanuric acid — 2007-04
- ILO/WHO ICSC 0437: Sodium dichloroisocyanurate — 2022-12
- FAO JECFA monograph: Sodium dichloroisocyanurate specifications
- FAO JECFA 61st meeting: Sodium dichloroisocyanurate, Chemical and Technical Assessment — 2004
- Kingnod calcium hypochlorite 70% safety data sheet (EU format) — 2020-06-01
- SGS test report MCHQD2500737-01A on a calcium hypochlorite sample submitted by Kingnod
- OSHA Brief 3514: Hazard Communication Standard — Safety Data Sheets
- Public Health England: Management of spa pools — controlling the risks of infection, Part 2 — 2017-01